• 12 kinds of Power
Measurements for Power Control and Applicable
to Power Quality Control including Harmonics Analysis.
• One click easy-to-use operation helps
complicated setting and processing of large data
through the setting / analyzing software provided
as accessory.
• Direct communication with PC via USB cable
• Built-in Input / Output Function of external
signal enables the signal transmission to alarms.
• 2-way power supply by AC and Battery,
and Nickel hydrogen battery usable with rechargeable
function.
• Pull / Insert of CF card possible whenever
on recording under the function of memory backup
device (1GB usable).
• Can monitor insulation at leakage current
by using optional leak clamp sensors.
• Built-in Print Screen Function enables
to record display screen (Records 512 screens
by using CF card: 1 screen 40KB).
• Can display Waveform and Vector, and can
confirm the wiring connection, too.
• Complies fully with International Safety
Standards
IEC61010-1 CAT.III 600V.
Voltage : ±0.3%rdg ±0.2%f.s.
Current : ±0.3%rdg ±0.2%f.s.
+ Accuracy of Clamp sensor
Active power : ±0.3%rdg ±0.2%f.s.
+ Accuracy of Clamp sensor (Power factor 1)
Influence
of power factor
|±1.0%rdg (reading at
power factor 0.5 against power factor 1)
• All necessary Power
Measurements : V, A, W, VA, Var, Wh, VAh, Varh,
cos ?, In, Hz.
• Recording function with "integration
time" selectable from 1 second to 1 hour.
• Internal non volatile Memory for non-stop
recording up to 10 days.
• Accepts Removable Compact Flash Memory
up to 128MB for non-stop recording up to 5 years.
• Supplied with interface software for downloading
data to PC via USB.
• Four wiring con.gurations : 3 Phase 4
Wires, 3 Phase 3 Wires, single Phase 3 Wire and
2 Wires.
• Wide screen with back light Multi-Display
system for simultaneous measurements.
• Double power supply system : from AC Line
and from Alkaline battery with approx. 7 hours
of battery life.
• Demand function for Energy-Saving measurements.
• Designed to Safety Standard IEC 61010-1
CAT.III 600V.
12
kinds of power measurements
Voltage (RMS), Current (RMS),
active power, apparent power, reactive power,
active energy, apparent energy, reactive energy,
power factor (cos ?), frequency , demand measurement,
current flowing on the neutral line (Only on3
phase 4 wire measurement)
Regenerative
electric power can be measured
Detection of consumption power
and regenerative electric power Regenerative electric
power: This is the electric power which is generated
by private power generator, and is supplied to
electric power company.
The
electric power and the power factor for each phase
can be confirmed
Monitoring of operation for
each phase.
Recording
internal can be set between 1 second and 1 hour
8306(Compact Flash card 64MB).
8307(Compact Flash card 128MB).
8308(CF Card reader). 8124,8125,8126,8127(Clamp
sensor).
Wide range of clamp sensor up to 1000A on
request.