Clamp Sensors
 
     
 
 
8129

Flexible Clamp Sensor

8129-01 (for 1ch)
8129-02 (for 2ch)
8129-03 (for 3ch)

• Flexible for various test fields
• Can measure AC current up to 3000A
• Flexible and light weight by the air core coil used at the sensor part
• Measurable conductor size:
max F150mm
• Designed to meet the international safety standard
IEC61010-1 CAT.III 600V

Applicable model 5010/5020,6300

 

  8129-01 (for 1ch) 8129-02 (for 2ch) 8129-03 (for 3ch)
Conductor size max. F150mm
Rated current 300/1000/3000A
Output voltage 300A Range : AC500mV/AC300A (1.67mV/A)
1000A Range : AC500mV/AC1000A (0.5mV/A)
3000A Range : AC500mV/AC3000A (0.167mV/A)
Accuracy ±1.0%rdg (45~65Hz)
Phase Shift within ±1°
Withstand voltage AC5350V for 5 seconds
300A Range : 30~300A (45~65Hz)
1000A Range : 100~1000A (45~65Hz)
3000A Range : 300~3000A (45~65Hz)
Cable length Sensor part : approx. 2m
Output cable : approx. 1m
Output connector MINI DIN 6PIN
Operating temperature & humidity ranges 0~50ºC, relative humidity 85% or less (no condensation)
Output impedance 100R or less
Applicable standards IEC 61010-1, IEC 61010-2-032 CAT.III 600V Pollution degree2,
IEC 61326
Dimensions 111(L) x 61(W) x 43(D) mm (except for protrusions)
Weight Approx. 410g Approx. 680g Approx. 950g
Accessories Instruction Manual
7199 (Output Cable) x1
9137 (Carrying Case)
Instruction Manual
7199 (Output Cable) x2
9137 (Carrying Case)
Instruction Manual
7199 (Output Cable) x3
9137 (Carrying Case)
 
8121

Load current detection type clamp sensor

Conductor size Ø24
Rated current AC 100A
Output voltage AC 500mV/100A (AC 5mV/A)
Accuracy ±2.0%rdg±0.3mV (50/60Hz)
±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage AC 3540V for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~40ºC, less than 85% RH (without condensation)
Output impedance Approx. 9.5O
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 300V pollution degree 2
Dimensions 97(L) x 59(W) x 26(D) mm
Weight Approx.150g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8122

Load current detection type clamp sensor

Conductor size Ø55
Rated current AC 1000A
Output voltage AC 500mV/1000A (AC 0.5mV/A)
Accuracy ±2.0%rdg±0.3mV (50/60Hz)
±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage AC 5350V for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~40ºC, less than 85% RH (without condensation)
Output impedance Approx. 1.5R
Applicable standards IIEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 600V pollution degree 2
Dimensions 170(L) x 105(W) x 48(D) mm
Weight Approx.360g
Accessories 9094 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8123

Load current detection type clamp sensor

Conductor size Ø40
Rated current AC 500A
Output voltage AC 500mV/500A (AC 1mV/A)
Accuracy ±2.0%rdg±0.3mV (50/60Hz)
±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage AC 5350V for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~40ºC, less than 85% RH (without condensation)
Output impedance Approx. 1.9R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 600V pollution degree 2
Dimensions 128(L) x 81(W) x 36(D) mm
Weight Approx.260g
Accessories 9094 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8146

Leakage current & Load current detection type clamp sensor

Conductor size Ø24
Rated current AC 30A
Output voltage AC 1500mV/30A (AC 50mV/A)
Accuracy 0~15A
±1.0%rdg±0.1mV (50/60Hz)
±2.0%rdg±0.2mV (40Hz~1kHz)

15~30A
±5.0%rdg (50/60Hz)
±10.0%rdg (45Hz~1kHz)

Withstand voltage AC 3540V for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 90R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 300V pollution degree 2
Dimensions 100(L) x 60(W) x 26(D) mm
Weight Approx.150g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8147

Leakage current & Load current detection type clamp sensor

Conductor size Ø40
Rated current AC 70A
Output voltage AC 3500mV/70A (AC 50mV/A)
Accuracy 0~40A
±1.0%rdg±0.1mV (50/60Hz)
±2.0%rdg±0.2mV (40Hz~1kHz)

40~70A
±5.0%rdg (50/60Hz)
±10.0%rdg (45Hz~1kHz)

Withstand voltage AC 3540V for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 100R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 300V pollution degree 2
Dimensions 128(L) x 81(W) x 36(D) mm
Weight Approx.240g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8148

Leakage current & Load current detection type clamp sensor

Conductor size Ø68
Rated current AC 100A
Output voltage AC 5000mV/100A (AC 50mV/A)
Accuracy 0~80A
±1.0%rdg±0.1mV (50/60Hz)
±2.0%rdg±0.2mV (40Hz~1kHz)

80~100A
±5.0%rdg (50/60Hz)
±10.0%rdg (45Hz~1kHz)

Withstand voltage AC 3540V for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 60R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 300V pollution degree 2
Dimensions 186(L) x 129(W) x 53(D) mm
Weight Approx.510g
Accessories 9094(Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8128

Load current detection type clamp sensor

Conductor size Ø24
Rated current AC 5A (Max.50A)
Output voltage AC 50mV/5A [Max.500mV/50A] (AC 10mV/A)
Accuracy ±0.5%rdg±0.1mV (50/60Hz)
±1.0%rdg±0.2mV (40Hz~1kHz)
Phase Shift within ±2.0º (45~65Hz)
Withstand voltage AC 3540V for 5 seconds
Cable length Approx. 3m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 20R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 300V pollution degree 2
Dimensions 100(L) x 60(W) x 26(D) mm
Weight Approx.160g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8127

Load current detection type clamp sensor

Conductor size Ø24
Rated current AC 100A
Output voltage AC 500mV/100A (AC 5mV/A)
Accuracy ±0.5%rdg±0.1mV (50/60Hz)
±1.0%rdg±0.2mV (40Hz~1kHz)
Phase Shift within ±2.0º (45~65Hz)
Withstand voltage AC 3540V for 5 seconds
Cable length Approx. 3m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 10R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 300V pollution degree 2
Dimensions 100(L) x 60(W) x 26(D) mm
Weight Approx.160g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8126

Load current detection type clamp sensor

Conductor size Ø40
Rated current AC 200A
Output voltage AC 500mV/200A (AC 2.5mV/A)
Accuracy ±0.5%rdg±0.1mV (50/60Hz)
±1.0%rdg±0.2mV (40Hz~1kHz)
Phase Shift within ±1.0º (45~65Hz)
Withstand voltage AC 5350V for 5 seconds
Cable length Approx. 3m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 5R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 600V pollution degree 2
Dimensions 128(L) x 81(W) x 36(D) mm
Weight Approx.260g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8125

Load current detection type clamp sensor

Conductor size Ø40
Rated current AC 500A
Output voltage AC 500mV/500A (AC 1mV/A)
Accuracy ±0.5%rdg±0.1mV (50/60Hz)
±1.0%rdg±0.2mV (40Hz~1kHz)
Phase Shift within ±1.0º (45~65Hz)
Withstand voltage AC 5350V for 5 seconds
Cable length Approx. 3m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 2R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 600V pollution degree 2
Dimensions 128(L) x 81(W) x 36(D) mm
Weight Approx.260g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8124

Load current detection type clamp sensor

Conductor size Ø68
Rated current AC 1000A
Output voltage AC 500mV/1000A (AC 0.5mV/A)
Accuracy ±0.5%rdg±0.1mV (50/60Hz)
±1.0%rdg±0.2mV (40Hz~1kHz)
Phase Shift within ±1.0º (45~65Hz)
Withstand voltage AC 5350V for 5 seconds
Cable length Approx. 3m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 1R
Applicable standards IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 600V pollution degree 2
Dimensions 186(L) x 129(W) x 53(D) mm
Weight Approx.510g
Accessories 9094 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8141

Load current detection type clamp sensor

Conductor size Ø24
Rated current AC 1000mA
Output voltage AC 100mV/1000mA (AC 100mV/A)
Accuracy ±1.0%rdg±0.1mV (50/60Hz)
±2.0%rdg±0.1mV (40Hz~1kHz)
Withstand voltage AC 3540V (50/60Hz) for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 180R
Applicable standards IEC 61010-1,
IEC 61010-2-032,
CAT.III 300V pollution degree 2
Dimensions 100(L) x 60(W) x 26(D) mm
Weight Approx.150g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8142

Load current detection type clamp sensor

Conductor size Ø40
Rated current AC 1000mA
Output voltage AC 100mV/1000mA (AC 100mV/A)
Accuracy ±1.0%rdg±0.1mV (50/60Hz)
±2.0%rdg±0.1mV (40Hz~1kHz)
Withstand voltage AC 3540V (50/60Hz) for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 200R
Applicable standards IEC 61010-1,
IEC 61010-2-032,
CAT.III 300V pollution degree 2
Dimensions 128(L) x 81(W) x 36(D) mm
Weight Approx.240g
Accessories 9095 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
8143

Load current detection type clamp sensor

Conductor size Ø68
Rated current AC 1000mA
Output voltage AC 100mV/1000mA (AC 100mV/A)
Accuracy ±1.0%rdg±0.1mV (50/60Hz)
±2.0%rdg±0.1mV (40Hz~1kHz)
Withstand voltage AC 3540V (50/60Hz) for 5 seconds
Cable length Approx. 2m
Output connector MINI DIN 6pin
Operating temperature ranges 0~50ºC, less than 85% RH (without condensation)
Output impedance Approx. 120R
Applicable standards IEC 61010-1,
IEC 61010-2-032,
CAT.III 300V pollution degree 2
Dimensions 186(L) x 129(W) x 53(D) mm
Weight Approx.490g
Accessories 9094 (Portable case), Instruction manual, Cable marker
Option 7146 (Banana F4 adjuster plug)
7185 (Extension Cable)

Product Catalogue

 
 
  Back to Kyoritsu Main Page