• True RMS can measure
and indicate distorted waveforms
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min
& max value
• REL(relative value) function to indicate
the measurement variation
• DUTY function
• Data Hold function, Auto Power Off function
• Continuity with buzzer and Diode Check
function
• Capacity measurement of capacitors
• Current ranges are protected by fuses
• Designed to meet international safety
standards
IEC61010-1 CAT.III 300V / CAT.II 600V
DC V
600.0mV/6.000/60.00/600.0/600V
(Input Impedance: 10M, 100M only 600mV)
±0.5%±2dgt (600.0mV/6.000/60.00/600.0V)
±0.8%±3dgt (600V)
• Temperature measurement,
selectable for ºC and ºF
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min
& max value
• REL(relative value) function to indicate
the measurement variation
• DUTY function
• Data Hold function, Auto Power Off function
• Continuity with buzzer and Diode Check
function
• Capacity measurement of capacitors
• Current ranges are protected by fuses
• Designed to meet international safety
standards
IEC61010-1 CAT.III 300V / CAT.II 600V
-50~300ºC (-58~572ºF)
(with the use of Temperature probe 8216)
Note: KEW 1011 can measure max. 700ºC
In order to measure over 300ºC, please
use a K-type temperature probe available in
the market.
• Capable of measuring
AC and DC currents up to 60A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
• Sleep function to save battery consumption.
• Designed to international safety standard
IEC61010-1 CAT.III 300V
• Capable of measuring
AC and DC currents up to 100A with OPEN CLAMP
SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
• Sleep function to save battery consumption.
• Designed to international safety standard
IEC61010-1 CAT.III 300V
• Compact in Size, Light
in Weight and Simple in Use.
• Double moulding provides comfortable and
good feeling in hand.
• Penlight illuminates brightly the point
to be measured, even in dark place.
• Backlight LCD is highly visible, even
in darkness.
• Auto power-off function saves the battery
life.
• Unique wrapping mechanism for test lead
in the rear side compartment.
• Unique protection mechanism for the test
prod for safety.
• All ranges including Ohm range are protected
against overload voltage of 600V.
• Designed in conformity with International
safety standards IEC61010-1:2001 CAT.III 600V
AC
V
4/40/400/600V(4
Range auto) ±1.3%rdg|±5dgt
(4/40V) (50/60Hz) ±1.6%rdg|±5dgt
(400/600V) (50/60Hz)
DC V
400m/4/40/400/600V(5 Range
auto) ±0.8%rdg|±5dgt(400mV~400V)
±1.0%rdg|±5dgt(600V)
Ohms
400/4k/40k/400k/4M/40M
(6 Range auto) ±1.0%rdg|±5dgt
(400R~4M) ±2.5%rdg|±5dgt
(40M)
Diode check
Test voltage approx. 0.3~1.5V
Continuity check
Buzzer sounds when resistance
is 120R or less
Capacitance
50n/500n/5µ/50µ/100µF
(5 Range auto) ±3.5%rdg|±10dgt(50nF)
±3.5%rdg|±5dgt(500n~50µF)
±4.5%rdg|±5dgt(100µF)
Frequency
5/50/500/5k/50k/200kHz
±0.1%rdg|±5dgt (Measurable input:
1.5Vrms or more)
• Display : 4000 counts.
• Auto range.
• Diode test feature.
• Capacitance test feature.
• Continuity test.
• Automatically turns power off in about
15 minutes to conserve battery life.
• Designed to international safety standard
IEC61010-1 CAT.III 300V.
• Display : 4000 counts.
• Auto range and manual range selector provided.
(with range hold feature)
• Diode test feature.
• Capacitance test feature.
• Relative measurement.
• Resistance range provides audible continuity
test.
• Automatically turns power off in about
30 minutes to conserve battery life.
• Direct current measurement up to 10A AC
and DC.
• With Holster.
• Designed to international safety standard
IEC61010-1 CAT.III 300V.
7060(Temperature
Probe)
7069(10kV High Voltage Probe)
1109
Analogue
Multimeters
• Mirrored scale for
easy and accurate reading.
• Fuse and diode protected circuit (except
15A AC range).
• Output terminal to cut off DC component
when measuring AC voltage.
• Safety designed input terminals and test
leads.
• Mirrored scale for
easy and accurate reading.
• Fuse and diode protected circuit (except
15A AC range).
• Output terminal to cut off DC component
when measuring AC voltage.
• Safety designed input terminals and test
leads.
DC V
0.5/5/25/100/250/500V(5kO/V)
±3% of FS
AC V
10/50/250/500V(2.5kO/V)
±3% of FS
DC A
200µA/2.5/25/250mA
±3% of FS ±5% of FS(250mA)
Ohms
3/30/300k ±3%
of scale length
Temperature
-20ºC~+150ºC
±5ºC(0ºC~+100ºC)
±10ºC(other ranges)
(with the use of Temperature probe 7060)
• High sensitivity DC20kO/V.
• Polarity selector switch.
• 1m drop-proof heavy duty designed taut-band
movement.
• Can measure line voltage up to AC 600V.
(Voltage to ground MAX AC300V) (Protected by 600V
ceramic fuse against accidental overload)
• Continuity buzzer, battery check, LED
check, temperature measurement function.
• Skeleton type robust and clear case with
carrying handle furnished as standard accessory.
DC V
0.3V(16.7kO/V)
±3% of FS
3/12/30/120/300/600V(20kO/V) ±3%
of FS
AC V
12V(9kO/V) ±4%
of FS
30/120/300/600V(9kO/V) ±3% of FS
DC A
60µA/30/300mA
±3% of FS
O
3/30/300kO ±3%
of scale length
Continuity
buzzer
Buzzer sounds below 100O
LED
10mA approx. at 0 O
(at 3V of battery voltage)
Temperature
-20ºC~+150ºC
|±3% of scale length (0ºC~+100ºC)
|±4% of scale length (other ranges)
(with the use of Temperature probe 7060)