Multimeters
 
     
 
 
1012

 

Digital Multimeters

• True RMS can measure and indicate distorted waveforms
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation
• DUTY function
• Data Hold function, Auto Power Off function
• Continuity with buzzer and Diode Check function
• Capacity measurement of capacitors
• Current ranges are protected by fuses
• Designed to meet international safety standards
IEC61010-1 CAT.III 300V / CAT.II 600V

DC V 600.0mV/6.000/60.00/600.0/600V
(Input Impedance: 10M, 100M only 600mV)
±0.5%±2dgt (600.0mV/6.000/60.00/600.0V)
±0.8%±3dgt (600V)
AC V 6.000/60.00/600.0/600V
(Input Impedance: 10M)
±1.5%±5dgt (6.000V)
±1.2%±3dgt (60.00/600.0V)
±1.5%±5dgt (600V)
DC A 600/6000µA/60/600mA/6/10A
±1.2%±3dgt(600/6000µA/60/600mA)
±2.0%±5dgt(6/10A)
AC A 600/6000µA/60/600mA/6/10A
±1.5%±4dgt(600/6000µA/60/600mA)
±2.2%±5dgt(6/10A)
Ohms 600R/6/60/600kO/6/60M
±1.0%±2dgt(600R/6/60/600kO/6M)
±2.0%±3dgt(60M)
Continuity buzzer 0~600R(Buzzer sounds below 100R)
Diode Check 2.8V Release Voltage:Approx. 0.4mA Test Current
Capacitance 40/400nF/4/40/400/4000µF
Frequency 10/100/1000Hz/10/100/1000kHz/10MHz
DUTY 0.1~99.9% (Pulse width/Pulse period)
±2.0%±2dgt (~10kHz)
Display 6040 Counts
Withstand Voltage AC 3700V / 1min.
Applicable Standard IEC 61010-1 CAT.III 300V Pollution degree 2
IEC 61010-1 CAT.II 600V Pollution degree 2
IEC 61010-031
IEC 61326
Power Source R6P(1.5V) × 2 (Auto-power-OFF within 15 minutes)
Dimensions 161(L) × 82(W) × 50(D)mm
Weight Approx. 280g
Accessories KTL04 (Test Lead)
0.8A/600V (Ceramic Fuse) × 1built-in
10A/600V (Ceramic Fuse) × 1built-in
R6P × 2
Instruction Manual

Product Catalogue

 
1011

Digital Multimeters

• Temperature measurement, selectable for ºC and ºF
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation
• DUTY function
• Data Hold function, Auto Power Off function
• Continuity with buzzer and Diode Check function
• Capacity measurement of capacitors
• Current ranges are protected by fuses
• Designed to meet international safety standards
IEC61010-1 CAT.III 300V / CAT.II 600V

DC V 600.0mV/6.000/60.00/600.0/600V
(Input Impedance: 10MO, 100MO only 600mV)
±0.5%±2dgt (600.0mV/6.000/60.00/600.0V)
±0.8%±3dgt (600V)
AC V 6.000/60.00/600.0/600V
(Input Impedance: 10MO)
±1.0%±3dgt (6.000/60.00/600.0V)
±1.5%±3dgt (600V)
DC A 600/6000µA/60/600mA/6/10A
±1.2%±3dgt(600/6000µA/60/600mA)
±2.0%±5dgt(6/10A)
AC A 600/6000µA/60/600mA/6/10A
±1.5%±4dgt(600/6000µA/60/600mA)
±2.2%±5dgt(6/10A)
Ohms 600R/6/60/600k/6/60M
±1.0%±2dgt(600R/6/60/600k/6M)
±2.0%±3dgt(60M)
Continuity buzzer 0~600R(Buzzer sounds below 100R)
Diode Check 2.8V Release Voltage:Approx. 0.4mA Test Current
Capacitance 40/400nF/4/40/400/4000µF
Frequency 10/100/1000Hz/10/100/1000kHz/10MHz
DUTY 0.1~99.9% (Pulse width/Pulse period)
|±2.0%±2dgt (~10kHz)
Temperature -50~300ºC (-58~572ºF)
(with the use of Temperature probe 8216)
Note: KEW 1011 can measure max. 700ºC
In order to measure over 300ºC, please use a K-type temperature probe available in the market.
Display 6040 Counts
Withstand Voltage AC 3700V / 1min.
Applicable Standard IEC 61010-1 CAT.III 300V Pollution degree 2
IEC 61010-1 CAT.II 600V Pollution degree 2
IEC 61010-031
IEC 61326
Power Source R6P(1.5V) × 2 (Auto-power-OFF within 15 minutes)
Dimensions 161(L) × 82(W) × 50(D)mm
Weight Approx. 280g
Accessories KTL04 (Test Lead)
8216 (K-type Temperature probe)
0.8A/600V (Ceramic Fuse) × 1built-in
10A/600V (Ceramic Fuse) × 1built-in
R6P × 2Instruction Manual

Product Catalogue

 
KEW MATE 2000

 

Digital Multimeters

• Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
• Sleep function to save battery consumption.
• Designed to international safety standard IEC61010-1 CAT.III 300V

Range Measuring Range Accuracy
DC A 60A 0~60A ±2%rdg±5dgt
AC A 60A 0~60A ±2%rdg±5dgt (50/60Hz)
DC V 340mV
3.4V
34V
340V
600V
0~600V
(5 Autoranging)
±1.5%rdg±4dgt
AC V 3.4V
34V
340V
600V
0~600V
(4 Autoranging)
±1.5%rdg±5dgt
(50-400Hz)
Resistance
Ohms
340 Ohms
(Continuity)
3.4k
34k
340k
3.4M
34M
0~33.99M
(6 Autoranging)
Buzzer sounds at 30R±10R
±1%rdg±3dgt


(±5%rdg±5dgt)
(±15%rdg±5dgt)

Frequency
(Hz)
AC A 3.4kHz
10kHz
0~10kHz
(2 Autoranging)
±0.1%rdg±1dgt
AC V 3.4kHz
34kHz
300kHz
0~300kHz
(3 Autoranging)
±0.1%rdg±1dgt
Maximum AC/DC
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor Size Ø6mm max.
Withstand Voltage 3700V AC for 1 minute
Safety Standard IEC61010-1 CAT.III 300V Pollution Degree 2
IEC61010-2-031
IEC61010-2-032
IEC61326-1
Power Source Two R03 or equivalent (DC1.5V) batteries
Dimensions 128(L) × 87(W) × 21(D)mm
Weight 210g approx.
Accessories R03(1.5V) × 2
Instruction Manual
Optional Soft Case

Product Catalogue

 
KEW MATE 2001

 

Digital Multimeters

• Capable of measuring AC and DC currents up to 100A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
• Sleep function to save battery consumption.
• Designed to international safety standard IEC61010-1 CAT.III 300V

Range Measuring Range Accuracy
DC A 100A 0~100A ±2%rdg±5dgt
AC A 100A 0~100A ±2%rdg±5dgt (50/60Hz)
DC V 340mV
3.4V
34V
340V
600V
0~600V
(5 Autoranging)
±1.5%rdg±4dgt
AC V 3.4V
34V
340V
600V
0~600V
(4 Autoranging)
±1.5%rdg±5dgt
(50-400Hz)
Resistance
Ohms
340 Ohms
(Continuity)
3.4k
34k
340k
3.4M
34M
0~33.99M
(6 Autoranging)
Buzzer sounds at 30R±10R

±1%rdg±3dgt


(±5%rdg±5dgt)
(±15%rdg±5dgt)

Frequency
(Hz)
AC A 3.4kHz
10kHz
0~10kHz
(2 Autoranging)
±0.1%rdg±1dgt
AC V 3.4kHz
34kHz
300kHz
0~300kHz
(3 Autoranging)
±0.1%rdg±1dgt
Maximum AC/DC
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor Size Ø10mm max.
Withstand Voltage 3700V AC for 1 minute
Safety Standard IEC61010-1 CAT.III 300V Pollution Degree 2
IEC61010-2-031
IEC61010-2-032
IEC61326-1
Power Source Two R03 or equivalent (DC1.5V) batteries
Dimensions 128(L) × 91(W) × 27(D)mm
Weight 220g approx.
Accessories R03(1.5V) × 2
Instruction Manual
Optional Soft Case

Product Catalogue

 
1030

 

Digital Multimeters

• Compact in Size, Light in Weight and Simple in Use.
• Double moulding provides comfortable and good feeling in hand.
• Penlight illuminates brightly the point to be measured, even in dark place.
• Backlight LCD is highly visible, even in darkness.
• Auto power-off function saves the battery life.
• Unique wrapping mechanism for test lead in the rear side compartment.
• Unique protection mechanism for the test prod for safety.
• All ranges including Ohm range are protected against overload voltage of 600V.
• Designed in conformity with International safety standards IEC61010-1:2001 CAT.III 600V

AC V
4/40/400/600V(4 Range auto)
±1.3%rdg|±5dgt (4/40V) (50/60Hz)
±1.6%rdg|±5dgt (400/600V) (50/60Hz)
DC V 400m/4/40/400/600V(5 Range auto)
±0.8%rdg|±5dgt(400mV~400V)
±1.0%rdg|±5dgt(600V)
Ohms 400/4k/40k/400k/4M/40M (6 Range auto)
±1.0%rdg|±5dgt (400R~4M)
±2.5%rdg|±5dgt (40M)
Diode check Test voltage approx. 0.3~1.5V
Continuity check Buzzer sounds when resistance is 120R or less
Capacitance 50n/500n/5µ/50µ/100µF (5 Range auto)
±3.5%rdg|±10dgt(50nF)
±3.5%rdg|±5dgt(500n~50µF)
±4.5%rdg|±5dgt(100µF)
Frequency 5/50/500/5k/50k/200kHz
±0.1%rdg|±5dgt (Measurable input: 1.5Vrms or more)
Duty 0.1~99.9%
±2.5%rdg|±5dgt (Pulse width / Pulse cycle)
Data hold The measured value can be hold by pressing Data hold button
Battery voltage warning When the battery voltage drops to 2.4V|±0.2V or less
Auto power-off Built-in
Safety standard / EMC IEC61010-1: 2001 CAT.III 600V
IEC61010-031
IEC61326-1
Power source Button type battery LR44(SR44)1.5V × 2
Dimensions 190(L) × 39(W) × 31(D)mm
Weight Approx. 100g (including batteries)
Accessories Carrying case, LR44(1.5V) × 2, Instruction manual

Product Catalogue

 
1018 (Soft case type) / 1018H (Hard case type)

 

 

 

Digital Multimeters

• Display : 4000 counts.
• Auto range.
• Diode test feature.
• Capacitance test feature.
• Continuity test.
• Automatically turns power off in about 15 minutes to conserve battery life.
• Designed to international safety standard IEC61010-1 CAT.III 300V.

DC V
400mV/4/40/400/600V(Input Impedance 10MO)
±0.8%rdg±5dgt(400mV/4/40/400V)
±1.0%rdg±5dgt(600V))
AC V 4/40/400/600V(Input Impedance 10MO)
±1.3%rdg±5dgt(4/40V)
±1.6%rdg±5dgt(400/600V)
Hz 10/100Hz/1/10/100/200kHz
Ohms 400R/4/40/400k/4/40M
±1.0%rdg±5dgt(400R/4/40/400kO/4M)
±2.5%rdg±5dgt(40M
Diode Test 4V Release Voltage:Approx. 0.4mA Test Current
Capacitance Test 4nF/40nF/400nF/4µF/40µF/200µF
Continuity buzzer 400O(Buzzer sounds below 120R)
Withstand Voltage 3700V AC for 1 minute
Standard IEC 61010-1 CAT.III 300V
IEC 61010-2-031
IEC 61326-1
Power Source LR44(1.5V) × 2
Dimensions 107(L) × 54(W) × 10(D)mm
Weight 70g approx.
Accessories LR44× 2
Instruction Manual
1018(Soft Case)
1018H(Hard Case)
 
1009

Digital Multimeters

• Display : 4000 counts.
• Auto range and manual range selector provided.
(with range hold feature)
• Diode test feature.
• Capacitance test feature.
• Relative measurement.
• Resistance range provides audible continuity test.
• Automatically turns power off in about 30 minutes to conserve battery life.
• Direct current measurement up to 10A AC and DC.
• With Holster.
• Designed to international safety standard IEC61010-1 CAT.III 300V.

DC V

400mV/4/40/400/600V(Input Impedance 10MO)
±0.6%rdg±4dgt(400mV/4/40/400V)
±1.0%rdg±4dgt(600V)
AC V 400mV/4/40/400/600V(Input Impedance 10MO)
±1.6%rdg±4dgt(20~400mV)
±1.3%rdg±4dgt(4/40V)
±1.6%rdg±4dgt(400/600V)
Hz 5.12/51.2/512Hz/5.12/51.2/512kHz/5.12/10MHz
DC A 400/4000µA/40/400mA/4/10A
±2.0%rdg±4dgt(400/4000µA)
±1.0%rdg±4dgt(40/400mA)
±1.6%rdg±4dgt(4/10A)
AC A 400/4000µA/40/400mA/4/10A
±2.6%rdg±4dgt(400/4000µA)
±2.0%rdg±4dgt(40/400mA/4/10A))
Ohms 400R/4/40/400k/4/40M
±1.0%rdg±4dgt(400R/4/40/400k/4M)
±2.0%rdg±4dgt(40M)
Diode Test 4V Release Voltage:Approx. 0.4mA Test Current
Capacitance Test 40nF/400nF/4µF/40µF/100µF
Continuity buzzer 400O(Buzzer sounds below 100R)
Withstand Voltage 3700V AC for 1 minute
Standard IEC 61010-1 CAT.III 300V
IEC 61010-2-031
IEC 61326-1
Power Source R6P(1.5V) × 2
Dimensions 155(L) × 75(W) × 33(D)mm
Weight 260g approx.
Accessories KTL04 Test Leads
0.5A/250V fuse× 1
10A/250V fuse× 1
R6P× 2
Instruction Manual

Product Catalogue

 
1108

Analogue Multimeters

• Sloping front panel for easy reading.
Tilt stand to allow for an optimum viewing angle.
• Fuse and diode protected circuitry.

DC V
0.25/1/2.5/5/10/25/50/100/250/500/1000V
±3% of FS (20k/V)
AC V 1/2.5/5/10/25/50/100/250/500/1000V(20k/V)
±3% of FS
±5%(1V, 2.5V)
DC A 50µA/2.5/25/500mA/10A
±3% of FS
AC A 10A
±3% of FS
Ohms 5/50/500kO/5M
±3% of scale length
Decibel -20~+22dB
Temperature -20ºC~+150ºC
±5ºC(0ºC~+100ºC)
±10ºC(other ranges)
(with the use of Temperature probe 7060)
Battery Test 2.5V(10R load)
Power Source R6P(AA)(1.5V) × 2
Dimensions 188(L) × 102(W) × 45(D)mm
Weight

350g approx.

Accessories 7066(Test Leads)
8901(0.5A/250V fuse) × 2
9012(Carrying Case)
R6P(AA) × 2
Instruction Manual
Optional 7060(Temperature Probe)
7069(10kV High Voltage Probe)
 
1109

Analogue Multimeters

• Mirrored scale for easy and accurate reading.
• Fuse and diode protected circuit (except 15A AC range).
• Output terminal to cut off DC component when measuring AC voltage.
• Safety designed input terminals and test leads.

DC V
0.1/0.5/2.5/10/50/250/1000V
±3% of FS (20kO/V)
AC V 10/50/250/1000V(9kohms/V)
±3% of FS
DC A 50µA/2.5/25/250mA
±3% of FS
AC A 15A
±3% of FS
Ohms 2/20k/2/20M
±3% of scale length
Decibel -10~+62dB
hFE 0~100R(R× 10)
±3% of scale length
Withstand Voltage 6000V AC for 1 minute
Power Source R6P(AA)(1.5V) × 2
6F22(9V) × 1
Dimensions 150(L) × 100(W) × 47(D)mm
Weight

330g approx.

Accessories 7085(Test Leads)
8901(0.5A/250V fuse) × 2
R6P(AA) × 2
6F22 × 1
Instruction Manual
Optional 9076(Carrying Case)
 
1106

Analogue Multimeters

• Mirrored scale for easy and accurate reading.
• Fuse and diode protected circuit (except 15A AC range).
• Output terminal to cut off DC component when measuring AC voltage.
• Safety designed input terminals and test leads.

DC V
0.5/5/25/100/250/500V(5kO/V)
±3% of FS
AC V 10/50/250/500V(2.5kO/V)
±3% of FS
DC A 200µA/2.5/25/250mA
±3% of FS
±5% of FS(250mA)
Ohms 3/30/300k
±3% of scale length
Temperature -20ºC~+150ºC
±5ºC(0ºC~+100ºC)
±10ºC(other ranges)
(with the use of Temperature probe 7060)
Battery Test 2V(20R load)
Withstand Voltage 3000V AC for 1 minute
Power Source R6P(AA)(1.5V) × 1
Dimensions 130(L) × 85(W) × 38(D)mm
Weight 175g approx.
Accessories

7066(Test Leads)
8901(0.5A/250V fuse) × 1
R6P(AA) × 1
Instruction Manual

Optional 9059(Carrying Case)
7060(Temperature Probe)
 
1110

 

Analogue Multimeters

• High sensitivity DC20kO/V.
• Polarity selector switch.
• 1m drop-proof heavy duty designed taut-band movement.
• Can measure line voltage up to AC 600V.
(Voltage to ground MAX AC300V) (Protected by 600V ceramic fuse against accidental overload)
• Continuity buzzer, battery check, LED check, temperature measurement function.
• Skeleton type robust and clear case with carrying handle furnished as standard accessory.

DC V
0.3V(16.7kO/V) ±3% of FS
3/12/30/120/300/600V(20kO/V)
±3% of FS
AC V 12V(9kO/V) ±4% of FS
30/120/300/600V(9kO/V)
±3% of FS
DC A 60µA/30/300mA
±3% of FS
O 3/30/300kO
±3% of scale length
Continuity buzzer Buzzer sounds below 100O
LED 10mA approx. at 0 O
(at 3V of battery voltage)
Temperature -20ºC~+150ºC
|±3% of scale length (0ºC~+100ºC)
|±4% of scale length (other ranges)
(with the use of Temperature probe 7060)
Battery Test 1.5V(0.7~2V)
|±3% of FS (10O load)
Maximum
Circuit Voltage
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Safety Standard IEC61010-1 CAT.III 300V Pollution Degree 2
CAT.II 600V Pollution Degree 2
IEC61010-2-031
Withstand Voltage

3700V AC for 1 minute

Power Source R6P(AA)(1.5V) × 2
Dimensions 94(L) × 140(W) × 39(D)mm
Weight 280g approx.
Accessories 7066(Test Leads)
8923(F500mA/600V fuse) × 2
R6P(AA) × 2
9103(Carrying Case)
Instruction Manual
Optional 7060(Temperature Probe)
 
     
  Back to Kyoritsu Main Page