• Designed to meet international
safety standards
IEC 61243-3/IEC 61010-1
Measurement Category (CAT.) IV 600V
• Self-Diagnostic test
• AC and DC voltage tests up to 690V with
LED
• Polarity indication
• Single-pole phase test
• Phase rotation test
• Double molding gives comfortable grip
• Continuity test
• Auto-power ON/OFF
• Pen light for illuminating measurement
points
• Variable distance in socket, 16.7mm or
19.0mm
• Variable probe Tips, 1.6mm or 4mmf
• Probe cover protects user and probe Tips
• IP65 (IEC 60529)
Voltage
Test
Voltage
Range
12~690V AC/DC
Nominal Voltage
12/24/50/120/230/400/690V
AC(45~400Hz), DC(±)
Tolerance
(Threshold Voltage)
Light on at more than:
7±3V (12V LED)
18±3V (24V LED)
37.5±4V (50V LED)
75%±5% of nominal voltage
(120/230/400/690V LED)
Response Time
<0.5s at 100% of each
nominal voltage
Peak Current
ls<3.5mA (at 690V)
Internal Battery
Consumption
Approx. 33mA (battery
3V, measuring 690V AC)
Battery Life
Approx. 2500 operations
(30s ON/240s OFF duty)
Single-Pole
Phase Test
Voltage Range
100~690V AC (45~100Hz)
180~690V AC (100~400Hz)
Phase
Rotation Test
System
Three-phase 4-wire system
200~690V phase-to-phase
(100~400V earth-to-phase)
AC 50/60Hz
• Designed to meet international
safety standards
IEC 61243-3/IEC 61010-1
Measurement Category (CAT.) IV 600V
• Self-Diagnostic test
• AC and DC voltage tests up to 690V with
LEDs and LCD
• Polarity indication
• Single-pole phase test
• Phase rotation test
• Double molding gives comfortable grip
• Continuity test
• Auto-power ON/OFF
• Pen light for illuminating measurement
points
• Variable distance in socket, 16.7mm or
19.0mm
• Variable probe Tips, 1.6mm or 4mmf
• Probe cover protects user and probe Tips
• IP65 (IEC 60529)
Voltage
Test
Voltage
Range
12~690V AC/DC
LED
Nominal
Voltage
12/24/50/120/230/400/690V
AC(45~400Hz), DC(±)
Tolerance
(Threshold Voltage)
Light on at more than:
7±3V (12V LED)
18±3V (24V LED)
37.5±4V (50V LED)
75%±5% of nominal voltage
(120/230/400/690V LED)
Response Time
<0.5s at 100% of each
nominal voltage
LCD
Range/Resolution
(Auto-range)
300V (7.0~299.9V)/0.1V
690V (270~759)/1V
Accuracy (23±5ºC)
±1.5V (7~100V)
±1%±5dgt (100~690V)
AC (45~400Hz), DC(±)
Overrange
Indication
"OL"
Response Time
<2s at
90% of each voltage
Peak
Current
ls<3.5mA (at 690V)
Measurement
Duty
30s ON (operation
time)
240s OFF (recovery time)
Internal
Battery Consumption
Approx. 33mA (battery
3V, measuring 690V AC)
Battery
Life
Approx. 2500 operations
(30s ON/240s OFF duty)
Single-Pole
Phase Test
Voltage
Range
100~690V AC (45~100Hz)
180~690V AC (100~400Hz)
Phase
Rotation Test
System
Three-phase
4-wire system
200~690V phase-to-phase
(100~400V earth-to-phase)
AC 50/60Hz